Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Braz. dent. sci ; 26(1): 1-9, 2023. tab, ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1411432

RESUMO

Objective: to analyze the stress distribution in a 3D model that simulates second molar mesialization using two different types of mini-implants. Material and Methods: a mandible bone model was obtained by recomposing a computed tomography performed by a software program. The cortical and trabecular bone, a lower second molar, periodontal ligament, orthodontic tube, resin cement and the mini-implants were designed and modeled using the Rhinoceros 4.0 software program. The characteristics of self-drilling orthodontic mini-implants were: one with 7 mm length, 1 mm transmucosal neck section and 1.6 mm diameter and another with 5 mm length and 1.5 mm diameter. A total of 235.161 and 224.505 elements were used for the mesh. These models were inserted into the bone block and then subjected to loads of 200 cN (centinewton). The results were calculated and analyzed by the Ansys 17.0 software program for qualitative verification through displacement and maximum principal stress maps. Results: it was possible to observe that the periodontal ligament presented low displacement and stress values. However, the physiological values presented are among those capable to provide orthodontic movement, with compression and tensile area visualization staggered between 0.1 and -0.1 MPa (megapascal). Conclusion: within the limitations of the study, the mini-implants tested showed similar results where the load on the tooth allowed dental displacement (molar mesialization), with a tendency to rotate it, theoretically allowing the second molar to take the location of the first molar. (AU)


Objetivo: analisar a distribuição de tensões em um modelo 3D que simula a mesialização do segundo molar usando dois tipos diferentes de mini-implantes. Material e Métodos: um modelo de osso mandibular foi obtido por recomposição de uma tomografia computadorizada realizada por um software. O osso cortical e trabecular, um segundo molar inferior, ligamento periodontal, tubo ortodôntico, cimento resinoso e os mini-implantes foram projetados e modelados no software Rhinoceros 4.0. As características dos mini-implantes ortodônticos auto perfurantes foram: um com 7 mm de comprimento, 1 mm de secção transmucosa e 1,6 mm de diâmetro e outro com 5 mm de comprimento e 1,5 mm de diâmetro. Para a malha, foram utilizados 235.161 e 224.505 elementos. Esses modelos foram inseridos no bloco ósseo e então submetidos a cargas de 200 cN (centinewton). Os resultados foram calculados e analisados pelo software Ansys 17.0 para verificação qualitativa por meio de mapas de deslocamento e tensões máximas principais. Resultados: foi possível observar que o ligamento periodontal apresentou baixos valores de deslocamento e tensões. Porém, os valores fisiológicos apresentados são capazes de proporcionar movimentação ortodôntica, com visualização da área de compressão e tração escalonada entre 0,1 e -0,1 MPa (megapascal). Conclusão: dentro das limitações do estudo, os mini-implantes testados apresentaram resultados semelhantes onde a carga sobre o dente permitiu o deslocamento dentário (mesialização do molar), com tendência a girá-lo, permitindo teoricamente que o segundo molar ocupe do lugar do primeiro molar (AU)


Assuntos
Avulsão Dentária , Implantes Dentários , Análise de Elementos Finitos , Procedimentos de Ancoragem Ortodôntica , Aparelhos Ortodônticos Fixos
2.
Braz. dent. sci ; 24(1): 1-8, 2021. tab, ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1145549

RESUMO

Objective: The aim of this study was to compare the bond strength of High-Translucency zirconia (HT) and lithium disilicate dental ceramics, under different surface treatments. Material And Methods: For this, ceramics were divided into groups: Control Group (C) (n = 5), lithium disilicate sheets, conditioned with 10% hydrofluoric acid, followed by application of 37% phosphoric acid, silane and universal adhesive application; Group HTAI (n = 5), HT zirconia sheets were blasted with silica oxide, followed by the application of universal adhesive; Group HTPAI (n = 5), HT zirconia sheets were blasted with silica oxide, followed by the application of non-thermal plasma and universal adhesive and the HTP Group (n = 5), HT zirconia received only the application of non-thermal argon plasma. Subsequently, the specimens of each group were subjected to a cementation process with resin cement, obtaining cylinders. After 24 h of storage, in distilled water, at 37°C, the specimens were subjected to a mechanical micro-shear test. The data obtained were submitted to ANOVA One-way followed by the Tukey test (5%). Results: The HTP Group was excluded from the statistical analysis, as adhesions failed within the storage period. In addition, it was not possible to verify a statistical difference between the control group C and the experimental groups HTAI and HTPAI. Conclusion: The results showed that the applicability of high translucency zirconia can potentially be compared to the lithium disilicate bond strength, when submitted to the same surface treatments, except for the plasma application, which alone was not effective (AU)


Objetivo: O objetivo deste estudo foi comparar a resistência adesiva das cerâmicas dentárias de zircônia de alta translucidez e dissilicato de lítio. Materiais e Métodos: Para isso, cerâmicas foram divididas em grupos: Grupo Controle (C) (n = 5), lâminas de dissilicato de lítio, condicionadas com ácido fluorídrico 10%, seguido de aplicação do ácido fosfórico 37%, aplicação de silano e aplicação do adesivo universal; Grupo HTAI (n = 5), lâminas de zircônia HT foram submetidas ao jateamento com óxido de sílica, seguido da aplicação do adesivo universal; Grupo HTPAI (n = 5), lâminas de zircônia HT foram submetidas ao jateamento com óxido de sílica, seguido da aplicação do plasma não térmico e do adesivo universal e o Grupo HTP (n = 5), lâminas de zircônia HT receberam apenas a aplicação do plasma não térmico de argônio. Posteriormente, os espécimes de cada grupo foram submetidos a um processo de cimentação com cimento resinoso, obtendo-se cilindros. Após 24h, de armazenamento em água destilada a 37°C, os espécimes foram submetidos a ensaio mecânico de microcisalhamento. Os dados obtidos foram submetidos à ANOVA 1-fator seguido pelo teste de Tukey (5%). Resultados: O Grupo HTP foi descartado da análise estatística, pois as adesões falharam dentro do período de armazenamento. Além disso, não foi possível verificar diferença estatística entre o grupo controle C e os experimentais HTAI e HTPAI. Conclusão: Os resultados mostraram que a aplicabilidade das zircônias de alta translucidez pode potencialmente ser comparada à resistência adesiva da cerâmica de dissilicato de lítio, quando submetidas aos mesmos tratamentos de superfície, com exceção da aplicação de plasma, que isoladamente não foi efetiva (AU)


Assuntos
Ligas Metalo-Cerâmicas , Adesivos Dentinários , Cimentos de Resina , Cimentos Dentários
3.
Braz. dent. sci ; 23(2,supl): 1-7, 2020.
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1100315

RESUMO

We are going through a health crisis, a pandemic caused by the new corona virus (SarsCOV2), which causes the disease COVID 19. This pandemic has also had a negative impact on the world economy, with dental offices being directly affected. Given this, the objective of this article is to bring important points in the strategy of management of dental clinics and how to be prepared to face the moment of crisis and also for the resumption. We believe that actions should be guided on three fronts: survival, sustainability and new future. The scenario is new, but with the right actions, the prospects for recovery are good. The important thing is to stay focused on what we have control, to do our best for the financial health of the business, however, remember that human health comes first, that any financial recovery will only be positive when people's lives and health are being preserved. (AU)


Estamos passando por uma crise de saúde, uma pandemia causada pelo novo corona vírus (SarsCOV2), causador da doença COVID 19. Esta pandemia, trouxe um impacto negativo também na economia mundial, sendo os consultórios odontológicos diretamente atingidos. Diante disso, o objetivo deste artigo é trazer pontos importantes na estratégia de gestão de clínicas odontológicas e como estar preparado para enfrentar o momento de crise e também para a retomada. Acreditamos que as ações devam ser pautadas em três frentes: sobrevivência, sustentabilidade e novo futuro. O cenário é incerto, porém com ações acertadas as perspectivas de retomada são boas. O importante é mantermos o foco naquilo que temos controle, fazer nosso melhor para a saúde financeira dos negócios, porém, lembrar que a saúde humana esta em primeiro lugar, que qualquer retomada financeira só será positiva quando as vidas e a saúde das pessoas estiverem sendo preservadas. (AU)


Assuntos
Coronavirus , Clínicas Odontológicas
4.
Braz. dent. sci ; 22(4): 483-487, 2019. tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1024436

RESUMO

Objective: This study aimed to evaluate and compare the retention force of individual clasps made from polyamide, acetate resin and cobalt-chrome for removable partial dentures. Material and methods: Three groups of clasps were fabricated: Cr-Co ­ 10 conventional chrome-cobalt metal clasps; Ac ­ 10 clasps with reciprocal arms and occlusal rests in chrome-cobalt and retentive arms in acetate resin; and Poly - 10 clasps with reciprocal arms and occlusal rests in chrome-cobalt and retentive arms in polyamide resin. Through the tensile test, in a universal testing machine, the initial retention force of the specimens was obtained and then clasps were cycled 7200 times, immersed in artificial saliva (60 months of simulated clinical use). After cycling, tensile test was performed. Results: All groups presented a retention decrease after the cycling. Ac presented a large reduction in retentive force (61.43%), followed by Cr-Co (26.5%) and Poly (12.09%). Conclusions: Aesthetic clasps of polyamide can be used in clinical cases where the anterior supporting teeth will not be essential for good retention of the removable partial denture because this clasp showed to be more resistant than the acetate resin. (AU)


Objetivo: Este estudo teve como objetivo avaliar e comparar a força de retenção de grampos individuais feitos de poliamida, resina de acetato e cromo-cobalto para próteses parciais removíveis. Material e Métodos: Três grupos de grampos foram fabricados: Cr-Co ­ 10 grampos metálicos convencionais de cromo-cobalto; Ac - 10 grampos com apoios e braço de oposição em cromocobalto e braços de retenção em resina de acetato; e Poly - 10 grampos com apoios e braço de oposição em cromo cobalto e braço de retenção em resina de poliamida. Por meio do teste de tração, em uma máquina de ensaio universal, a força de retenção inicial dos espécimes foi obtida e então, os grampos foram ciclados 7200 vezes, imersos em saliva artificial (60 meses de uso clínico simulado). Após a ciclagem, o teste de tração foi realizado. Resultados: Todos os grupos apresentaram diminuição da retenção após a ciclagem. Ac apresentou uma grande redução na força retentiva (61,43%), seguida por Cr-Co (26,5%) e Poly (12,09%). Conclusões: Grampos estéticos de poliamida podem ser usados em casos clínicos em que os dentes de suporte anteriores não serão essenciais para uma boa retenção da prótese parcial removível, pois esse grampo mostrouse mais resistente que os de resina de acetato (AU)


Assuntos
Grampos Dentários , Materiais Dentários , Prótese Parcial Removível
5.
Braz. dent. sci ; 20(2): 146-151, 2017. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-846451

RESUMO

Removable Partial Dentures (RPD) with dual path of insertion are designed to overcome conventional RPD esthetic limitations, through the use of proximal undercuts for rigid direct retainers. Therefore, dual path RPD is considered a variation of conventional RPD. This paper reports a clinical case where proper function as well as excellent esthetics were obtained with this type of RPD. (AU)


Próteses parciais removíveis (PPR) com dupla trajetória de inserção são próteses projetadas para superar limitações estéticas das próteses convencionais, utilizando-se retentores diretos rígidos nas áreas retentivas proximais dos dentes suportes. Desta forma, a PPR com dupla trajetória da inserção é considerada uma variação da PPR tradicional. O objetivo deste artigo é relatar um caso clínico onde se obteve uma resolução funcional e altamente estética através deste tipo de PPR..(AU)


Assuntos
Humanos , Prótese Parcial Removível
6.
Braz. dent. sci ; 20(3): 87-92, 2017. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-868107

RESUMO

Objetivo: Este estudo teve como objetivo avaliar a retenção do grampo de resina de acetato quando comparado ao grampo metálico. Material e métodos: Para isso, 10 grampos metálicos Co-Cr convencionais (Ackers) e 20 de resina de acetate foram confeccionados. Os grampos de resina de acetato foram constituídos por braços de oposição, suporte e retenção feitos de CoCr. Dos 20 grampos estéticos, 10 tiveram a espessura do braço de retenção diminuídos para torná-los mais estéticos. A força de retenção inicial dos espécimes foi testada em uma máquina de teste universal através de teste de tração. Depois disso, os espécimes foram submetidos a 7.000 ciclos, cada um, em uma máquina adaptada, imersos em saliva artificial, por 36 meses, simulando uso clínico de uma prótese parcial removível. Os dados foram tabulados para análise estatística da eficácia de retenção. Resultados: Após ciclagem, os grampos de resina de acetato de 3 mm de espessura e 2 mm de espessura perderam mais retenção do que os grampos metálicos. O tipo de material (p = 0,0000) e a ciclagem (p = 0,0039) mostraram um efeito significativo, mas a interação material / ciclagem (p = 0,1436) não. Conclusões: Portanto, os grampos estéticos apresentaram força de retenção inferior à dos grampus metálicos. No entanto, os grampos estéticos podem ser utilizados em casos clínicos que requerem retenção mínima. (AU)


Objective: This study aimed to evaluate the retention of acetate resin clasp as when compared to metal clasp. Material and methods: For this purpose, we constructed 10 conventional Co-Cr metal clasps (Ackers) and 20 acetate resin clasps. The acetate resin clasps had the opposition, support and retaining arms made of Co-Cr. Of the 20 esthetic clasps, 10 had the thickness of the retention arm decreased to make it more esthetic. The initial retentive force of the specimens was tested in a universal testing machine through tensile test. After that, the specimens were subjected to 7,000 cycles, each one, in an adapted machine, immersed into artificial saliva, for 36 months of simulated clinical use of a removable partial denture. Data were tabulated for statistical analysis of the retention effectiveness. Results: After cycling, 3-mm-thick and 2-mmthick acetate resin clasps lost more retention than metal clasps. The material type (p=0.0000) and cycling (p=0.0039) showed a significant effect, but the material/cycling interaction (p=0.1436) did not. Conclusions: Therefore, esthetic clasps presented retention force lower than that of metal clasps. Notwithstanding, the esthetic clasps can be used in clinical cases requiring minimum retention. (AU)


Assuntos
Grampos Dentários , Prótese Parcial Removível
7.
Braz. dent. sci ; 17(4): 113-118, 2014. ilus
Artigo em Inglês | LILACS | ID: lil-742509

RESUMO

Today, the constant search for esthetics by most patients together with the difficult in obtaining a natural appearance at the anterior area, especially in Implantology, helps to develop new methodologies to solve these problems. The aim of this study was to demonstrate through case report the applicability of custom-made zirconia abutments in association with IPS eMax metalfree crowns. The prostheses at the anterior area of maxilla were made on four teeth and three implants. Implant abutments were customized in zirconia through CAD/CAM system. Metal-free crowns were obtained through IPS eMax system for all elements. The patient was clinically and radiographically followed-up at seven, 15, 30, 60 and 90 post-operative days, when it was observed the aesthetic-functional stability of the case. The final results met the expectations of the patient...


A busca pela estética constante do mundo contemporâneo que norteiam a maioria dos pacientes nos dias de hoje, aliado a dificuldade de se obter uma aparência natural em região anterior, principalmente quando se envolve implantes osseointegrados, fez com que novas técnicas, materiais e metodologias surgissem a fim de sanar essas dificuldades. Com o objetivo de demonstrar a aplicabilidade do uso de pilares personalizados em zircônia para casos de reabilitação estética anterior, foi descrito um caso clínico onde foi realizada uma reabilitação anterior de 7 elementos, sendo 4 dentes e 3 implantes, sendo os abutments dos implantes personalizados em zircônia pelo sistema CAD/CAM, juntamente com a utilização de coroas metal-freepelo sistema IPS eMax em todos os elementos reabilitados. A paciente após a finalização do caso passou por sessões de controle clínico após 15, 30, 60 e 90 dias onde juntamente com uma radiografia panorâmica, notou-se estabilidade estético-funcional do caso, estando a paciente satisfeita com o resultado final...


Assuntos
Humanos , Desenho Assistido por Computador , Implantação Dentária , Prótese Parcial Fixa
8.
Braz. dent. sci ; 17(2): 20-26, 2014. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-728133

RESUMO

Objective: The correct parallelism of guiding planes when constructing a Removable Partial Denture not only defines the axis of insertion and removal of the prosthesis, but also limits the possible axes of movement during functioning. Therefore, the purpose of the study was to compare some techniques and the use of an intra-oral device for those preparations. Material & Methods: Dummies were performed in a direct manner, simulating the absence of teeth 15, 45, 12 and 42. The four preparation techniques chosen were: Group 1 – freehand preparation; group 2 - guide pins; Group 3 - crown guides and Group 4 - parallel intraoral device – ParalAB. Results: No statistical difference was shown between the mean values of angles found for the freehand (82.85°) and guide pin (83.60°) groups. Also, no statistical significant difference was observed between the mean values of angles found for the resin cap (88.83) and intraoral device (88.58 º) groups; however they were superior to the findings for the freehand and guide pin groups. Conclusion: The studied methods are effective for what they were proposed; however, one should select the method according to the experience and skills, to promote the best results.


Objetivo: A transferência de planos de guia dos modelos de estudo para a boca é procedimento de extrema importância para o bom prognóstico de uma Prótese Parcial Removível. Objetivo: O objetivo do trabalho foi comparar diversas técnicas de confecção dos planos de guia, avaliando também a influencia da experiência do profissional executante. Material e Métodos: Manequins foram preparados simulando a ausência dos dentes 15, 45, 12 e 42. Foram realizadas 4 técnicas de preparo dos planos de guia, divididas em 4 Grupos: Grupo 1: técnica a mão livre; Grupo 2: técnica com pinos guias; Grupo 3: técnica com coroas guias; Grupo 4: Paralelômetro intra-oral – ParalAB. Estas técnicas foram executadas por profissionais com mais de 5 anos de formado e por alunos do ultimo ano de graduação em odontologia. Modelos de gesso foram obtidos antes e após a confecção dos preparos e comparados em uma máquina de leitura 3D. Resultados: Os resultados mostraram não haver diferença estatística entre os valores da angulação para o grupo 1 (82,85°) e grupo 2 (83,60°). Entre os grupos 3 (88,83°) e 4 (88,58°) também não houve diferença estatística, porém as técnicas dos Grupos 3 e 4 foram superiors às técnicas dos grupos 1 e 2. Em relação aos profissionais executantes, a experiência mostrou ter influência apenas nos grupos 1 e 2, não sendo significante nos grupos 3 e 4. Conclusão: Conclui-se que os métodos estudados foram efetivos para o propósito, e dependendo da sua experiência e habilidade, pode-se selecionar ao qual o profissional melhor se adpate, porém quando houver falta de experiência e confiança a técnica de coroas guias ou paralelômetro devem ser escolhidas.


Assuntos
Padrões de Prática Odontológica , Planejamento de Prótese Dentária , Prótese Parcial Removível
9.
Braz. dent. sci ; 16(4): 34-40, 2013. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-728097

RESUMO

Objective: The aim of this study was to evaluate the cuspal deflection of teeth restored directly and indirectly. Material and Methods: Forty sound maxillary premolar teeth were restored with composite and different base materials. Wide mesial-occlusal-distal cavity preparations were performed, with isthmus width of one third of the distance between the cuspal tips, 3 mm occlusal and a 5 mm interproximal preparation height. The teeth were divided into 4 groups (n = 10), according to the restoration type: G1) GIC-DCR (1 mm glass ionomer cement base and direct restoration using nanoparticulate composite); G2) FL-DCR (1 mm base of flowable composite resin and direct restoration using nanoparticulate composite); G3) GIC-ICR (1 mm glass ionomer cement base and indirect restoration using nanoparticulate composite GIC base); G4) FL-ICR (1 mm base of flowable composite resin and indirect restoration using nanoparticulate composite). The specimens were submitted to compressive load of 50 N on the buccal and lingual cusps, in a universal testing machine. The lingual cusp microstrain (με) measurements were executed by strain gauges. Results: The Kruskal-Wallis (5%) test was used and showed there were no significant differences among the microstrain values for the four study groups (G1 = 1250; G2 = 1075; G3 = 1279; G4 = 937). Conclusion: It could be concluded that the restorative techniques and the bases employed did not show any influences in cuspal deflection


Objetivo: O objetivo deste trabalho foi avaliar, por meio de medidores de tensão, a deflexão cuspídea sofrida por dentes restaurados, direta e indiretamente, com resinas compostas e diferentes materiais de base. Material e Métodos: Para o preparo dos corpos-de-prova (CP) foram utilizados 28 dentes pré-molares humanos íntegros, extraídos por razões ortodônticas que tiveram suas raízes embutidas em poliuretano de densidade semelhante a do osso e suas raízes recobertas por um espaçador visando simular o espaço referente ao ligamento periodontal. Na etapa seguinte os dentes receberam preparos cavitários do tipo mésio-ocluso-distais amplos e então restaurados direta e indiretamente com resina composta e dois diferentes materiais de base/forramento, resina flow e cimento de ionômero de vidro. Para a realização das medidas de deflexão das cúspides foram utilizados extensômetros lineares elétricos colados à face lingual de cada dente e submetidos a uma carga de 50 N aplicada por uma ponta romba de diâmetro de 3,0 mm, que promoveu compressão simultânea nas vertentes triturantes das cúspides vestibular e lingual, numa máquina universal de ensaios. Resultados: Foi realizado o teste de Kruskall-Wallis (5%) de significância e não foram encontradas diferenças estatísticamente significantes entre os grupos (G1 – 1250; G2 = 1075; G3 = 1279; G4 = 937). Conclusão: Pode-se concluir que o tipo de restauração bem como o tipo de base empregados nesse estudo não alteram a deflexão cuspídea dos dentes com restaurações amplas.


Assuntos
Humanos , Resinas Compostas , Cimentos de Ionômeros de Vidro
10.
Braz. dent. sci ; 15(1): 19-26, 2012. ilus, tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-728071

RESUMO

The study aimed to evaluate, through surface roughness and microhardness tests, the amount of damage caused by hydrochloric acid to restorative materials. Five different materials were used: direct composite resin (Z 350), indirect composite resin (Resilab Master), conventional glass-ionomer cement (GIC) (Vidrion R), resin modified GIC (Vitremer) and ceramic (Empress II). Twenty one specimens of each material were constructed and had their initial roughness and microhardness evaluated. Sixteen specimens of each material were immersed in a gastric fluid without enzymes simulating acid episodes. Other 5 specimens of each material were immersed in artificial saliva (control groups). After 7 days of immersion, the specimens had their surfaces evaluated again. Then, after another 21 days of immersion the specimens were submitted to a third mensuration. One specimen at each stage of the research was subjected to analysis in scanning electronic microscopy. The samples demonstrated changes in roughness and microhardness after the immersion of the restorative materials in the acid solution. The roughness results showed that for both glass ionomer cements, there was a significant difference between the first and last reading, with an increase in their roughness. In ceramic and direct resin materials, no significant difference among the periods was observed. Concerning to microhardness, the behavior of the materials showed a tendency towards decreasing hardness. The results showed the degradation of the restorative materials when exposed to acid episodes


O estudo teve como objetivo avaliar por meio dos testes de rugosidade superficial e microdureza os danos causados pelo ácido clorídrico em materiais restauradores. Utilizaram-se 5 materiais: resina composta direta (Z 350), resina composta indireta (Resilab Master), cimento de ionômero de vidro (CIV) convencional (Vidrion R), CIV modificado por resina (Vitremer) e uma cerâmica (Empress II). Vinte e um corpos de prova (cdp) de cada material foram confeccionados e tiveram suas superfícies iniciais avaliadas em um rugosímetro e um microdurômetro. Em seguida 16 cdp de cada material foram imersos em um suco gástrico sem enzimas simulando episódios ácidos. Outros 5 cdp de cada material serviram como grupo controle e ficaram imersos em saliva artificial. Após 7 dias de imersão os cdp tiveram suas superfícies novamente avaliadas. Após a segunda leitura, foi realizada imersão por mais 21 dias, completando um mês de experimento, e os cdp foram submetidos à terceira leitura de suas superfícies. Além disso, 1 cdp em cada fase da pesquisa foi submetido a uma análise em microscopia eletrônica de varredura (MEV) apenas como efeito ilustrativo. Amostras demonstraram alterações de rugosidade e microdureza diante da imersão de materiais restauradores em ácido. Os resultados de rugosidade mostraram que tanto para o ionômero convencional quanto para o modificado por resina houve uma diferença significante entre a primeira e a última leitura, havendo um aumento na rugosidade. Já para a cerâmica e a resina direta, não houve alteração significativa entre os períodos. O comportamento dos materiais mostrou uma tendência de diminuição da microdureza. Conclui-se que existe uma deterioração dos materiais restauradores frente a episódios ácidos


Assuntos
Materiais Dentários , Ácido Clorídrico
11.
Braz. dent. sci ; 15(1): 33-38, 2012. ilus, tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-728079

RESUMO

The aim of this in vitro study was to evaluate the bonding efficiency between two self-adhesive cements to enamel and dentine, with and without previous dental surface conditioning, before and after thermocycling. Thirty-six molars were divided into 3 experimental groups and 01 control group. The self-adhesive resin cements selected for the experimental groups were: RelyX Unicem (subgroups RE and RD) and Bifix SE (subgroups BE and BD). For control groups, a conventional resin cement, Variolink II (subgroups VRE and VRD), was used. The specimens were submitted to microtensile bond strength test. The results were submitted to analysis of variance (ANOVA) and Tukey’s test. The results showed statistically significant differences between VR group and the others before and after thermocycling. According to the results obtained, it can be concluded that self-adhesive cements, despite of their practicality and less sensitive technique concerning to cementation, have lower adhesive resistance when compared to conventional resin cements


O objetivo deste trabalho foi analisar in vitro a eficiência de adesão através de ensaio de microtração, de dois cimentos autocondicionantes (self-adhesive), sobre esmalte e dentina, antes e após termociclagem em comparação a um cimento resinoso convencional. Foram utilizados 36 terceiros molares, separados em grupos experimentais, sendo 2 grupos com cimentos resinosos auto-condicionantes (Rely X Unicem - 3M ESPE – subgrupos RE e RD) e Bifix SE - Voco/GHB – subgrupos BE e BD) e 1 grupo controle, com o cimento adesivo (Variolink II – Ivoclair - subgrupo VRE e VRD). Para a análise estatística do teste de adesão, foi utilizado ANOVA 3 fatores com teste de comparação múltipla de Tukey (5%). Os resultados evidenciaram diferença significante entre os grupos VR, dos demais grupos, antes e após termociclagem. De acordo com os resultados, podemos concluir que os cimentos autocondicionantes, apesar da sua praticidade, facilidade de técnica e menor susceptibilidade de hidrólise, ainda possuem menor resistência adesiva em relação aos cimentos resinosos convencionais.


Assuntos
Humanos , Cimentação , Cimentos Dentários
12.
Acta odontol. venez ; 50(1)2012. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-676737

RESUMO

Ya que este es un asunto muy discutido en la literatura, pero no completamente esclarecido El presente trabajo evaluó tridimensionalmente las alteraciones de impresiones con alginato tratadas con hipoclorito de sodio al 1%, a través de aerosol o inmersión. Se tomó la impresión de un padrón metálico simulando una arcada edéntula superior, con tres esferas fijadas en la región derecha, central e izquierda del reborde, y una cuarta esfera en el centro del paladar (puntos 1, 2, 3 y 4, respectivamente). Diez impresiones no fueron desinfectadas (G1=control). Diez impresiones fueron desinfectadas con aerosol de hipoclorito de sodio al 1% y enseguida fueron colocadas dentro de bolsas plásticas aguardándose 10 minutos (G2=aerosol), otras diez impresiones fueron inmersas en esta misma solución durante 10 minutos (G3=inmersión). Después, las impresiones de cada grupo fueron vaciadas con yeso tipo IV. Las mediciones fueron realizadas 24 horas después, en una máquina de coordenadas tridimensionales (Coordinate Mesuring Machine B504B, Mitutoyo), que calculó el centro de cada esfera y la distancia entre ellas. Los datos obtenidos fueron analizados por medio del análisis de varianza (ANOVA) y el test de Tukey (5%). No fueron encontradas diferencias estadísticamente significantes entre los tres grupos (G1,G2,G3) y el padrón metálico, sólo hubo diferencia entre G1 y G2, en dos de las seis distancias analizadas (1-2 y 1-3).


This study investigated the three dimensional changes of alginate impressions disinfected with 1% sodium hypoclorite by immersion and aerosol techniques, because there are controversies over it in literature. Impressions were taken from a metallic master model representing an edentulous maxillar arch with three spherical points (1, 2, 3) and the fourth one on the palate. Control samples (10 impressions) were poured directly using a special stone (control group). 10 impressions were disinfected by aerosol (aerosol group) and other 10 by immersion (immersion group), both techniques for 10 minutes. Next the stones were poured. After 24 hours the measurements were recorded by a Coordinate Measuring Machine, B504B, Mitutoyo. This machine determines the central of each sphere and the distances between them data was analyzed using ANOVA and Tukey tests (5%). The differences were significant between the control group and the aerosol group in two of six segments analyzed (1-2, 1-3). Significant differences were not found between any groups (immersion, aerosol e control) and the master model.


Assuntos
Humanos , Alginatos/análise , Desinfecção/métodos , Esterilização/métodos , Instrumentos Odontológicos/microbiologia , Produtos para Higiene Dental e Bucal
13.
RFO UPF ; 16(1)jan.-abr. 2011.
Artigo em Português | LILACS | ID: lil-593682

RESUMO

The objective was to evaluate the superficial roughness of a composite resin submitted to different surface treatments, in vitro. Thirty specimens were made with P60TM packable composite resin (3M ESPE), 6 mm thick and 3 mm in diameter. The samples were stored in distilled water for 7 days at 37 ºC and randomly assigned to two test groups. The baseline superficial roughness was determined with a profilometer. Fifteen specimens of each material were subjected to the following finishing and polishing procedures: Group I: multi-fluted burs/aluminum oxide disks (Diamond ProTM, FGM); Group II: multi-fluted burs/rubber tips (Enhance/PogoTM, Dent-sply). Time was limited to 20s per instrument. Following these procedures, it was accomplished a new reading and storage. Then the samples were polished with felt disks with diamond paste (Diamond ExcelTM, FGM), for 20s, and a surface sealant was applied (Biscover, BIS-CO). After all these procedures, the final roughness was determined. Statistical analysis was performed with RM ANOVA and Tukey´s tests (5%). Significant effects were found with both the polishing systems and the sealant (presence or absence). The polishing with Diamond Pro caused the greatest roughness on all composites (p < 0.05). After the application of Biscover the composite surfaces were smoother. This difference was significant for the group polished with Diamond Pro and not sig-nificant for the group polished with EnhanceTM/Pogo. It was concluded that the application of a surface sealant following polishing with aluminum oxide disks or abrasive rubbers results in a surface with smoothness superior to that obtained with these polishing devices alone.

14.
São José dos Campos; s.n; 2010. 140 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-587612

RESUMO

O objetivo do estudo foi avaliar quatro diferentes sistemas adesivos (Multi-Purpose, Single Bond, SE Plus e Easy Bond – 3M ESPE) no que se refere à resistência adesiva ao microcisalhamento na dentina bovina. Além de avaliar a citotoxicidade desses novos sistemas adesivos por meio do teste de barreira dentinária e ensaio de MTT em fibroblastos pulpares bovinos. Para o teste de microcisalhamento 80 dentes bovinos tiveram suas raízes seccionadas, foram embutidos em resina acrílica e tiveram a superfície vestibular desgastada expondo-se a dentina, sendo que em 40 dentes a espessura de dentina remanescente foi de 500μm e nos outros 40 de 200μm. Os cdp receberam então o procedimento adesivo de acordo com as instruções do fabricante e com auxílio de uma matriz metálica, cilindros de resina (Z 250 – 3M ESPE) de 0,8 mm de diâmetro e 1mm de altura foram construídos. Após 24h os cdp foram então submetidos ao ensaio de microcisalhamento. Para avaliar a citotoxicidade foi usado o teste de barreira dentinária. Células pulpares bovinas transformadas foram cultivadas em redes de nylon por 2 semanas, obtendo-se uma cultura de 3 dimensões. Essas culturas celulares foram separadas dos materiais testados por fatias de dentina de 500 e 200μm em um dispositivo de perfusão celular. Os materiais foram aplicados na porção cavitária do dispositivo de acordo com as instruções do fabricante, e um material de moldagem a base de silicona (President, Coltene) foi usado como controle negativo (100% de viabilidade celular). Após 24 h de período de exposição, a viabilidade celular foi mensurada fotometricamente (teste MTT). Por meio de estatística descritiva verificou-se que a melhor eficiência adesiva foi apresentada pelo adesivo auto-condicionante de um passo só, Easy Bond (21,06 MPa - 200μm; 27,01 MPa- 500μm) seguido pelo Single Bond (15,64 MPa - 200μm; 23,45 MPa- 500μm), SE Plus (18,23 MPa -200μm; 20,07 MPa- 500μm) e Multi Purpose (15,24 MPa - 200μm; 17,99 MPa - 500μm)...


The aim of this study was to evaluate four different adhesive systems (Multi-Purpose, Single Bond, SE Bond Plus and Easy - 3M ESPE) with regard tomicroshear bond strength to bovine dentin. In addition evaluate thecytotoxicity of these new adhesive systems by means of a dentin barrier test. To test microshear 80 bovine teeth had their roots sectioned and were embedded in acrylic resin. The buccal surface had been worn to expose the dentin, in 40 teeth the remaining dentin thickness was 500μm and 200μm in the other 40. The specimes received the adhesive procedure according to the manufacturer's instructions and with the aid of a metal matrix, cylinders ofresin (Z 250 - 3M ESPE) from 0.8 mm in diameter and 1mm in height were built. After 24h the specimes were then subjected to the micro shear testingTo evaluate the cytotoxicity, a dentin barrier test was used. SV3NeoB transfected bovine pulp derived cells were grown on nylon meshes for 2 weeks achieving a 3-dimensional cell culture as described. These cell cultures were separated from the test materials by dentin slices of 200 or500μm thickness in a cell cultures perfusion chamber. The materials were applied into the cavity part of the device according to manufacturer’sinstruction, and a silicon impression material (President, Coltene) served as a negative control material (100% cell viability). After a 24h exposure period,cell viability was measured photometrically (MTT test). Median values (plus 25% and 75% percentiles) of cell viability measurements (n=10) were statistically analyzed (Mann-Whitney test, = 0.05). Descriptive statistics found that the best bonding performance was presented by the single step adhesive Easy Bond (21.06 - 200μm, 27.01 - 500μm) followed by Single Bond (15.64 - 200μm; 23.45 - 500μm), SE Plus (18.23 - 200μm; 20.07 -500μm) and Multi Purpose (15.24 - 200μm; 17.99 - 500μm). More over, it was found that all the adhesive strength was greater...


Assuntos
Animais , Bovinos , Adesivos Dentinários , Resistência ao Cisalhamento
15.
Odonto (Säo Bernardo do Campo) ; 16(32): 98-104, jul.-dez. 2008. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-542934

RESUMO

Os conceitos de promoção de saúde, prevenção e a estética sedimentam a Odontologia atual, que atravessa um período de constante progresso. O surgimento das técnicas adesivas e materiais restauradores são um exemplo disso, devendo porém, sua aplicação clínica ser sustentada por bases científicas conseguidas por meio de pesquisas envolvendo novas técnicas e materiais. Devido a isso a resina composta foi o material mais intensamente pesquisado na última década com o intuito de melhorar suas propriedades negativas. Existem hoje no mercado diversos tipos de resinas, surgidas durante esse processo evolutivo, cada uma tendo suas indicações e limitações. As resinas mais atuais têm demonstrado, que não apenas a quantidade de carga vem sendo alvo de estudos como também seu formato, composição e distribuição, na tentativa de incrementar suas propriedades físicas e ópticas. Por isso, têm se dado bastante enfoque em diversas áreas sempre com o intuito de proporcionar aos pacientes melhores resultados estéticos, biológicos e funcionais. A nanotecnologia, que consiste na manipulação e medida de materiais na escala de abaixo de 100 nanômetros é um exemplo da exploração de novas áreas. Apesar de termos em mãos esse verdadeiro arsenal de materiais, nenhuma resina composta atingiu excelência de um material restaurador ideal. Prevêem-se para o início do milênio, melhoras consideráveis nas formulações das resinas compostas atuais e das novas que surgirão no sentido de melhorar as propriedades dos compósitos resinosos ampliando assim sua indicação.


In recent years the odontology suffered changes in some of its concepts, aesthetics and the search for conservatives treatments are part, nowadays, of the routine of the doctor’s offices and odontologic clinics. Because of this the composite resins was the material that has been more intensely searched in the last decade with intention to improve its negative properties. Types of resins, appeared during this evolutive process, each one having its indications and limitations. The most current resins have demonstrated, that not only the amount of load is theme for studies as well as its format, composition and distribution, in the attempt to develop its physical and optic properties. That is the reason why nowadays the nanotechnology, that consists of the manipulation and measure of materials in the scale below of 100 nanometers, is intensively being studied. These new materials present inorganic particles varying of 20-75nm, what diminishes the contraction of polymerization and it promotes satisfactory superficial smoothness. Although of having access to these new materials, no composite resin reached excellency of an ideal restoring material. They are foreseen for the beginning of the milenium, considerable improvements in the formularizations of current composite resins and the news that they will appear in the direction to improve the properties of the composite resins thus extending its indication.


Assuntos
Luz , Materiais Dentários , Resinas Compostas , Resinas Compostas/história , Resinas Compostas/química , Estética Dentária , Nanotecnologia
16.
PCL, Rev. Íbero Am. Prótese Clín. Lab. ; 8(39): 28-36, jan.-mar. 2006. tab, ilus, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-853143

RESUMO

O objetivo deste estudo foi verificar in vitro a resistência à remoção por tração de núcleos metálicos fundidos cimentados em dentes naturais após proteção da obturação endodôntica com etil-cianocrilato. Quarenta e oito dentes uniradiculados humanos extraídos tiveram a coroa seccionada padronizando as raízes em 16mm. Após o preparo biomecânico, obturação, aplicação de etil-cianocrilato (Super Bonder®) sobre o remanescente da obturação e preparo do conduto para retentor intra-radicular, a moldagem para a confecção dos núcleos metálicos fundidos foi realizada. Os grupos experimentais foram divididos de acordo com o agente cimentante utilizado: G1 (cimento de fosfato de zinco), G2 (cimento de inômero de vidro), G3 (Cimento resinoso - Enforce®) e G4 (Cimento resinoso - Panavia®). A força necessária para a remoção dos núcleos metálicos fundidos foi determinada utilizando-se uma máquina de ensaio universal (Emic). Os resultados foram analisados estatisticamente utilizando-se a ANOVA (5%). Não foram verificadas diferenças estatísticas nos valores das forças para a remoção dos núcleos metálicos fundidos entre os quatro grupos experimentais (p=0,09). A força necessária para a remoção dos núcleos metálicos fundidos pode ser classificada na seguinte ordem: G3 (105,57kgf), G1 (126,65kgf), G2 (135,80kgf) e G4 (148,30kgf)


Assuntos
Cimentação/métodos , Adesivos Dentinários , Técnica para Retentor Intrarradicular , Análise de Variância , Técnicas In Vitro , Materiais Restauradores do Canal Radicular , Resistência à Tração
17.
PCL, Rev. Íbero Am. Prótese Clín. Lab. ; 6(29): 102-108, jan.-fev. 2004. ilus, CD-ROM
Artigo em Espanhol, Português | BBO - Odontologia | ID: biblio-853066

RESUMO

Em casos onde há perda de elementos dentários e onde a reabilitação mais indicada é a prótese parcial removível (PPR), deparamo-nos com um sério problema, restabelecer a função sem prejuízos estéticos. Este trabalho visa a relatar a utilização do grampo Twin-Flex, uma alternativa para melhorar a estética sem descuidar dos aspectos biomecânicos das PPR


Assuntos
Humanos , Feminino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...